Last data update: May 06, 2024. (Total: 46732 publications since 2009)
Records 1-2 (of 2 Records) |
Query Trace: Roulo R[original query] |
---|
Rapid diagnostic testing for response to the monkeypox outbreak - Laboratory Response Network, United States, May 17-June 30, 2022
Aden TA , Blevins P , York SW , Rager S , Balachandran D , Hutson CL , Lowe D , Mangal CN , Wolford T , Matheny A , Davidson W , Wilkins K , Cook R , Roulo RM , White MK , Berman L , Murray J , Laurance J , Francis D , Green NM , Berumen RA3rd , Gonzalez A , Evans S , Hudziec M , Noel D , Adjei M , Hovan G , Lee P , Tate L , Gose RB , Voermans R , Crew J , Adam PR , Haydel D , Lukula S , Matluk N , Shah S , Featherston J , Ware D , Pettit D , McCutchen E , Acheampong E , Buttery E , Gorzalski A , Perry M , Fowler R , Lee RB , Nickla R , Huard R , Moore A , Jones K , Johnson R , Swaney E , Jaramillo J , Reinoso Webb C , Guin B , Yost J , Atkinson A , Griffin-Thomas L , Chenette J , Gant J , Sterkel A , Ghuman HK , Lute J , Smole SC , Arora V , Demontigny CK , Bielby M , Geeter E , Newman KAM , Glazier M , Lutkemeier W , Nelson M , Martinez R , Chaitram J , Honein MA , Villanueva JM . MMWR Morb Mortal Wkly Rep 2022 71 (28) 904-907 As part of public health preparedness for infectious disease threats, CDC collaborates with other U.S. public health officials to ensure that the Laboratory Response Network (LRN) has diagnostic tools to detect Orthopoxviruses, the genus that includes Variola virus, the causative agent of smallpox. LRN is a network of state and local public health, federal, U.S. Department of Defense (DOD), veterinary, food, and environmental testing laboratories. CDC developed, and the Food and Drug Administration (FDA) granted 510(k) clearance* for the Non-variola Orthopoxvirus Real-time PCR Primer and Probe Set (non-variola Orthopoxvirus [NVO] assay), a polymerase chain reaction (PCR) diagnostic test to detect NVO. On May 17, 2022, CDC was contacted by the Massachusetts Department of Public Health (DPH) regarding a suspected case of monkeypox, a disease caused by the Orthopoxvirus Monkeypox virus. Specimens were collected and tested by the Massachusetts DPH public health laboratory with LRN testing capability using the NVO assay. Nationwide, 68 LRN laboratories had capacity to test approximately 8,000 NVO tests per week during June. During May 17-June 30, LRN laboratories tested 2,009 specimens from suspected monkeypox cases. Among those, 730 (36.3%) specimens from 395 patients were positive for NVO. NVO-positive specimens from 159 persons were confirmed by CDC to be monkeypox; final characterization is pending for 236. Prompt identification of persons with infection allowed rapid response to the outbreak, including isolation and treatment of patients, administration of vaccines, and other public health action. To further facilitate access to testing and increase convenience for providers and patients by using existing provider-laboratory relationships, CDC and LRN are supporting five large commercial laboratories with a national footprint (Aegis Science, LabCorp, Mayo Clinic Laboratories, Quest Diagnostics, and Sonic Healthcare) to establish NVO testing capacity of 10,000 specimens per week per laboratory. On July 6, 2022, the first commercial laboratory began accepting specimens for NVO testing based on clinician orders. |
Performance of the Trioplex real-time RT-PCR assay for detection of Zika, dengue, and chikungunya viruses.
Santiago GA , Vazquez J , Courtney S , Matias KY , Andersen LE , Colon C , Butler AE , Roulo R , Bowzard J , Villanueva JM , Munoz-Jordan JL . Nat Commun 2018 9 (1) 1391 The emergence and spread of Zika virus (ZIKV) presented a challenge to the diagnosis of ZIKV infections in areas with transmission of dengue (DENV) and chikungunya (CHIKV) viruses. To facilitate detection of ZIKV infections, and differentiate these infections from DENV and CHIKV, we developed the Trioplex real-time RT-PCR assay (Trioplex assay). Here, we describe the optimization of multiplex and singleplex formats of the assay for a variety of chemistries and instruments to facilitate global standardization and implementation. We evaluated the analytical performance of all Trioplex modalities for detection of these three pathogens in serum and whole blood, and for ZIKV in urine. The limit of detection for the three viruses and in different RNA-extraction modalities is near 10(3) genome copy equivalents per milliliter (GCE/mL). Simultaneous testing of more than one specimen type from each patient provides a 6.4% additional diagnostic sensitivity. Overall, the high sensitivity of the Trioplex assay demonstrates the utility of this assay ascertaining Zika cases. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 06, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure